Products

New Energy Powers a Better Life.

Gas generators, CNG storage, refuelling and regulation, all built by Pulita. Download the specifications for every model.

0115–2,500 kVA

Pulita CNG generator sets with control panels lined up in the factory

CNG generator.

Pulita CNG generator sets run on compressed or pipeline natural gas for continuous 24-hour duty in hospitals, factories, estates and telecom sites. Larger plants are containerized and can be synchronised to match any load.

15–2,500kVA power range
Up to 44%peak efficiency
15 yearsdesign life
30,000 hmajor maintenance interval
Genset modelPrime powerkW / kVAStandby powerkW / kVARated voltageVPhaseRPMCNG consumptionm³/hDimensionsmm (L × W × H)WeightkgDatasheetper model
PLT-15GF15 kVA12/1513.2/16.5400/230 V3-phase15003.6 m³/h2200 × 1050 × 1400950PDF
PLT-20GF20 kVA16/2017.6/22400/230 V3-phase15004.8 m³/h2200 × 1050 × 1450980PDF
PLT-25GF25 kVA20/2522/27.5400/230 V3-phase15006 m³/h2200 × 1050 × 14501,000PDF
PLT-30GF30 kVA24/3026.4/33400/230 V3-phase15007.2 m³/h2200 × 1050 × 14501,000PDF
PLT-40GF40 kVA32/4035.2/44400/230 V3-phase15009.6 m³/h2400 × 1050 × 14501,050PDF
PLT-50GF50 kVA40/5044/55400/230 V3-phase150012 m³/h2400 × 1050 × 14501,080PDF
PLT-60GF60 kVA48/6052.8/66400/230 V3-phase150014.4 m³/h2800 × 1050 × 16501,400PDF
PLT-80GF80 kVA64/8070.4/88400/230 V3-phase150019.2 m³/h2800 × 1050 × 16501,600PDF
PLT-100GF100 kVA80/10088/110400/230 V3-phase150024 m³/h2800 × 1050 × 16501,640PDF
PLT-125GF125 kVA100/125110/137400/230 V3-phase150030 m³/h3000 × 1250 × 18002,500PDF
PLT-150GF150 kVA120/150132/165400/230 V3-phase150036 m³/h3000 × 1250 × 18002,560PDF
PLT-187.5GF187.5 kVA150/187.5165/206.25400/230 V3-phase150045 m³/h3100 × 1180 × 19602,600PDF
PLT-200GF200 kVA160/200176/220400/230 V3-phase150048 m³/h3300 × 1250 × 20602,800PDF
PLT-250GF250 kVA200/250220/275400/230 V3-phase150060 m³/h3600 × 1450 × 20602,900PDF
PLT-300GF300 kVA240/300264/330400/230 V3-phase150072 m³/h3800 × 1550 × 21603,200PDF
PLT-350GF350 kVA280/350308/385400/230 V3-phase150084 m³/h3800 × 1550 × 21603,380PDF
PLT-500GF500 kVA400/500440/550400/230 V3-phase1500116 m³/h4000 × 1550 × 22604,400PDF
PLT-625GF625 kVA500/625550/687.5400/230 V3-phase1500139.2 m³/h20 ft container10,500PDF
PLT-800GF800 kVA640/800704/888400/230 V3-phase1500185.6 m³/h20 ft container11,000PDF
PLT-1000GF1,000 kVA800/1000880/1100400/230 V3-phase1500224 m³/h20 ft container11,000PDF
PLT-1250GF1,250 kVA1000/12501100/1375400/230 V3-phase1500280 m³/h40 ft container16,000PDF
PLT-1800GF1,800 kVA1440/18001584/1980400/230 V3-phase1500403.2 m³/h40 ft container17,100PDF
PLT-2500GF2,500 kVA2000/25002200/2750400/230 V3-phase1000560 m³/hCustomised container35,000PDF

Click PDF for each model’s datasheet.

Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.

0215–300 kVA

Pulita LPG generator set beside its LPG storage tank

LPG generator.

LPG generator sets for sites without natural gas. They run from cylinders or a bulk tank, start with one button and cut fuel costs sharply compared with diesel. LPG generator sets can be configured for dual-fuel (LPG/CNG) operation based on customer requirements.

15–300kVA power range
Up to 5 kWhelectricity per kg of LPG
Propane + Butaneruns on both gases
Silentsoundproof canopy
Genset modelPrime powerkW / kVAStandby powerkW / kVARated voltageVPhaseRPMLPG consumptionkg/hDimensionsmm (L × W × H)WeightkgDatasheetper model
PLT-15GF15 kVA12/1513.2/16.5400/230 V3-phase15003 kg/h2200 × 1050 × 1400950PDF
PLT-20GF20 kVA16/2017.6/22400/230 V3-phase15004 kg/h2200 × 1050 × 1450980PDF
PLT-25GF25 kVA20/2522/27.5400/230 V3-phase15005 kg/h2200 × 1050 × 14501,000PDF
PLT-30GF30 kVA24/3026.4/33400/230 V3-phase15006 kg/h2200 × 1050 × 14501,000PDF
PLT-40GF40 kVA32/4035.2/44400/230 V3-phase15008 kg/h2400 × 1050 × 14501,050PDF
PLT-50GF50 kVA40/5044/55400/230 V3-phase150010 kg/h2400 × 1050 × 14501,080PDF
PLT-60GF60 kVA48/6052.8/66400/230 V3-phase150012 kg/h2800 × 1050 × 16501,400PDF
PLT-80GF80 kVA64/8070.4/88400/230 V3-phase150016 kg/h2800 × 1050 × 16501,600PDF
PLT-100GF100 kVA80/10088/110400/230 V3-phase150020 kg/h2800 × 1050 × 16501,640PDF
PLT-125GF125 kVA100/125110/137400/230 V3-phase150025 kg/h3000 × 1250 × 18002,500PDF
PLT-150GF150 kVA120/150132/165400/230 V3-phase150028.8 kg/h3100 × 1180 × 19602,560PDF
PLT-187.5GF187.5 kVA150/187.5165/206.25400/230 V3-phase150036 kg/h3100 × 1180 × 19602,600PDF
PLT-200GF200 kVA160/200176/220400/230 V3-phase150038.4 kg/h3300 × 1250 × 20602,800PDF
PLT-250GF250 kVA200/250220/275400/230 V3-phase150048 kg/h3600 × 1450 × 20602,900PDF
PLT-300GF300 kVA240/300264/330400/230 V3-phase150057.6 kg/h3800 × 1550 × 21603,200PDF

Click PDF for each model’s datasheet.

Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.

0315–1,250 kVA

Two Pulita biogas generator sets beside a biogas digester tower

Biogas generator.

Biogas generator sets turn gas from digesters, farms, food processing, wastewater and landfill into electricity. We configure each set to your gas analysis and pair it with gas treatment to remove H₂S and moisture.

15–1,250kVA power range
CH₄sized to methane content
Gas treatmentH₂S & moisture removal
CHPheat recovery optional
Genset modelPrime powerkW / kVAStandby powerkW / kVARated voltageVPhaseRPMBiogas consumptionDatasheetper model
PLT-15GF15 kVA12/1513.2/16.5400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-20GF20 kVA16/2017.6/22400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-25GF25 kVA20/2522/27.5400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-30GF30 kVA24/3026.4/33400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-40GF40 kVA32/4035.2/44400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-50GF50 kVA40/5044/55400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-60GF60 kVA48/6052.8/66400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-80GF80 kVA64/8070.4/88400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-100GF100 kVA80/10088/110400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-125GF125 kVA100/125110/137400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-150GF150 kVA120/150132/165400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-187.5GF187.5 kVA150/187.5165/206.25400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-200GF200 kVA160/200176/220400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-250GF250 kVA200/250220/275400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-300GF300 kVA240/300264/330400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-350GF350 kVA280/350308/385400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-500GF500 kVA400/500440/550400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-625GF625 kVA500/625550/687.5400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-800GF800 kVA640/800704/888400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-1000GF1,000 kVA800/1000880/1100400/230 V3-phase1500Depends on methane (CH₄) contentPDF
PLT-1250GF1,250 kVA1000/12501100/1375400/230 V3-phase1000Depends on methane (CH₄) contentPDF

Biogas consumption depends on the methane content of your gas: send us your gas analysis for exact figures. Click PDF for each model’s datasheet.

Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.

04200–7,000 scm

Pulita CNG cascade: cylinders in a white container frame with manifold piping

CNG cascade.

Pulita assembles 150–200 L cylinders into CNG cascades for on-site gas storage. Cascades feed gas generators through a PRMS, and store gas at MRUs and daughter stations, wherever there is no pipeline.

200–7,000scm storage capacity
200–250 barworking pressure
150–200 Lcylinder size
Modularscales with demand
Storage capacity200–7,000 scm
Cylinders150–200 L cylinders assembled into cascades
Working pressure200–250 bar
ConstructionModular steel frame, skid-mounted
UseOn-site CNG storage for gas generators, MRUs and daughter stations
Connects toPRMS and Pulita gas generator sets

Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.

05600–7,000 scm/h

Pulita MRU integrated daughter stations with CNG dispensers in the factory

MRU (integrated daughter station).

The MRU is a complete CNG daughter station on one skid: hydraulic compressor, gas storage, dispenser, metering, filtration and gas-leak alarms. It arrives ready to connect, needs no major civil works and can be relocated as demand grows.

600–7,000scm/h capacity
7 models600 to 7,000 scm/h
250 baroutput pressure
Skid-mountedfixed or mobile, hydraulic compressor
ModelRated capacityOutput pressureConfigurationDatasheetper model
MRU 600600 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF
MRU 1,2001,200 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF
MRU 2,5002,500 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF
MRU 3,2003,200 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF
MRU 4,0004,000 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF
MRU 6,0006,000 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF
MRU 7,0007,000 scm/h250 barSkid-mounted, hydraulic compressor · fixed or mobilePDF

Models: 600, 1,200, 2,500, 3,200, 4,000, 6,000 and 7,000 scm/h. Click PDF for each model’s datasheet.

Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.

0620–20,000 m³/h

Pulita PRMS cabinet open, showing regulators, filters and metering pipework

PRMS.

The pressure regulating and metering skid (PRMS) steps high-pressure CNG or pipeline gas down to the pressure your equipment needs, heats it to prevent freezing and meters every cubic metre for accurate cost control.

20–20,000m³/h flow range
250 barmax. inlet (CNG)
Meteringbuilt-in flow meter
Heatingprevents freezing
Flow range20 scm/h – 20,000 m³/h
InletHigh-pressure CNG (up to 250 bar) or pipeline gas
FunctionsMulti-stage pressure reduction, heating and flow metering
SafetySafety shut-off and relief valves
EnclosureWeatherproof, lockable cabinet or skid

Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.

Ready when you are

Stop burning cash on diesel.

Share your load and running hours. Our Lagos engineers will size the right generator, station or turnkey system and send a costed proposal.

Need a quote? Chat now